FusionPoD 700 is a rack-scale server with native liquid cooling design as it provides electricity, network and liquid for liquid-cooled servers.The overall architecture design adopts overhead cabling and underfloor water piping, which is more reliable; electricity, network and liquid are equipped with bus and blind mating design, significantly reducing the deployment efforts of cabinet and cables while improving O&M capability toward unmanned O&M. FusionPoD 700 rack-scale server is applicable to be deployed in the data centers that have high requirements on power efficiency and computing power intensity, and is also used in many application scenarios, such as cloud computing, virtualization and HPC when being configured with liquid-cooled servers.
Technical Specifications
• Full liquid cooling (including a front door and an RDHx): without casters: 2200 mm x 600 mm x 1400 mm (86.61 in. x 23.62 in. x 55.11 in.), with casters: 2250 mm × 600 mm × 1400 mm (88.58 in. x 23.62 in. x 55.11 in.)
• Board-level liquid cooling (including a front door and a normal back door): without casters: 2200 mm x 600 mm x 1200 mm (86.61 in. x 23.62 in. x 47.24 in.), with casters: 2250 mm × 600 mm × 1200 mm (88.58 in. x 23.62 in. x 47.24 in.)
• Available space: 47 U
• Server node: 36 x 1 U server nodes
• Switching node: 4 service switching nodes, 1 out-of-band management switching node, and 1+1 redundancy of service switching nodes
• Cabinet management node: 1 cabinet management module
• Power supply requirement: AC: 4 PSU modules in 2+2 redundancy mode, 380 V/32 A
• PSUs: 11+1 PSUs, 3 kW
• System maximum power consumption: 33 kW (backup) and 36 kW (no backup)
• Heat dissipation methods: liquid cooling + air cooling
• Operating temperature: 5°C to 45°C (41°F to 113°F) (ASHRAE Classes A1 to A3 compliant)
• Storage temperature (within three months): –30°C to +60°C (–22°F to +140°F)
• Storage temperature (within six months): –15°C to +45°C (5°F to 113°)
• Storage temperature (within one year): –10°C to +35°C (14°F to 95°F)
• Maximum temperature change rate: 20°C (36°F) per hour, 5°C (9°F) per 15 minutes
• Operating humidity: 8% to 90%
• Storage humidity (within three months): 8% to 85%
• Storage humidity (within six months): 8% to 80%
• Storage humidity (within one year): 20% to 75%
• Maximum change rate: 20% per hour
• Operating altitude: no more than 3050 m (10,006.56 ft)
– When the server configuration complies with ASHRAE Class A2 standards and the altitude is above 900 m (2,952.76 ft.), the operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.24 ft.)
– When the server configuration complies with ASHRAE Class A3 standards and the altitude is above 900 m (2,952.76 ft.), the operating temperature decreases by 1°C (1.8°F) for every increase of 175 m (574.15 ft)
– When the configuration complies with ASHRAE Class A4 standards and the altitude is above 900 m (2,952.76 ft.), the operating temperature decreases by 1°C (1.8°F) for every increase of 125 m (410.10 ft)
• Installation dimensions: cabinet projection area: 600 mm x 1350 mm (23.62 in. x 53.15 in.); reserve at least 1.2 m (3.94 ft) space for maintenance in front of and behind the cabinet
• Package size (W x H x D): 980 mm x 2405 mm x 1310 mm (38.58 in. x 94.69 in. x 51.47 in.) (except the front door and the back door)
• Fully loaded weight: 1200 kg
• Cabinet package weight: 34.8 kg
• Equipment room: no less than 1000 kg/m²
• Equipment room floor height: no less than 600 mm (23.62 in.)
• Manifold pipe installation port: 1-inch flange quick port
• RDHx pipe installation port: 1-inch flange quick port
• Manifold water supply requirement: pH value: ≥ 6.5; glycol-concentration: 25% ± 5% (volume concentration); total microorganism count: < 105 CFU/mL
Turbidity: no visible impurities in the filter net
• Manifold water supply temperature: 5℃ to 45℃ (41°F to 113°F)
• Manifold recommended water supply temperature: 30℃ (86°F)
• Manifold water supply flow: 32 LPM
• Manifold water supply maximum pressure: 350 kPa
• Manifold supply and return water pressure difference: 35 kPa at 25% glycol solution